Kit for assembling 4 cells scale





"PLT" SERIES' 350 Ohm NIKEL-PLATED LOAD CELL KITS FOR ASSEMBLING FLOOR SCALES


  "PLT" SERIES' 350 Ohm NIKEL-PLATED LOAD CELL KITS FOR ASSEMBLING FLOOR SCALES
 
DIMENSIONS - DECODING STANDARD CABLE
  • NOTE: dimensions in mm



  • Decoding of the standard cable colours

    Colour
    Function
      --
    SHIELD
    YELLOW
    OUTPUT +
    GREY
    SENSE +
    BROWN
    INPUT +
    WHITE
    OUTPUT -
    GREEN
    INPUT -
    PINK
    SENSE -
Ideal for creating platforms with 4 load cells of various sizes and capacities. The kit is made up of 4 350 Ohm IP67 nikel-plated load cells, OIML and NTEP approved, together with adjustable resting feet and an equalisation box.

LOAD CELL TECHNICAL FEATURES

  • Minimum load cell verification interval Vmin = EMax / 10.000
  • Maximum number of verification intervals nLC = 3000
  • Combined error 0,017% of Full Scale Output (F.S.)
  • Nonlinearity ± 0.02% FS
  • Hysteresis ± 0.02% FS
  • Repeatability ± 0.01% FS
  • Full Scale Output 2mV/V ± 0.5%
  • Zero balance ± 1% FS
  • Compensated Temperature Range -10°C/+50°C.
  • Operating Temperature Range -20°C/+60°C.
  • Creep error after 30 minutes <0,02% F.S.
  • Maximum tolerated excitation voltage 15 Vdc
  • Input Resistance 380 ± 20 Ohm
  • Output Resistance 350 ± 5 Ohm
  • Insulation Resistance >5000 MOhm
  • Safe Overload 150% F.S.
  • Ultimate Overload 300% F.S.
  • 6-wire shielded cable, 3.5m long, 5 mm diameter

RESTING FEET

  • Adjustable in height
  • Nikel-plated steel structure
  • Anti-slip base
  • Ipersanitizable
  • Fitted with locking bush

JUNCTION BOX

  • Built-in junction and equalisation board
  • IP67 protection from dust and water
  • 1 PG9 Cable gland and 4 PG7 Cable glands
DOWNLOAD
Available Versions
 CodeDescription
PLT405C3 Kit 4 x SBT500, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 500kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box).
PLT410C3 Kit 4 x SBT1000, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 1000kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box).
PLT420C3 Kit 4 x SBT2000, 4 x SBFA, 4 x BLKM12I, 1 x JB4Q (4 IP67 nikel-plated steel load cells with 2000kg capacity, 4 nikel-plated steel adjustable resting feet, 4 bushings and IP67 ABS junction box).
Junction Box / Boards - Load Cell cables
 CodeDescription
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m
LCCB5C(S1) LCCBC cable + 5m extension cable.
LCCB10C(S1) LCCBC cable + 10m extension cable.
Other options
 CodeDescription
GELBOX(S1) Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml.
WARNING:
For JB4Q, JB4QA, JBxQI and JBxQAI: 300ml of gel required

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.