Shear Beam





SBX-1KL SERIES SHEAR BEAM LOAD CELLS, 10000kg


  SBX-1KL SERIES SHEAR BEAM LOAD CELLS, 10000kg
 




DIMENSIONS - DECODING STANDARD CABLE
  • NOTE: dimensions in mm



  • Decoding of the standard cable colours

    Colour
    Function
      --
    SHIELD
    YELLOW
    OUTPUT +
    GREY
    SENSE +
    BROWN
    INPUT +
    WHITE
    OUTPUT -
    GREEN
    INPUT -
    PINK
    SENSE -
MAIN CERTIFICATIONS
  • OIML R60
  • Australian legal for trade certificate of approval (NMI S841)
Stainless steel approved shear beam load cells, with low-power 1000 Ohm output resistance for mobile battery applications.
Suitable for creating CE-M approved scales with 4 load cells, or for weighing tanks and hoppers, with the aid of its accessories.

CAPACITIES (kg): 10000.

OIML R60. C3 precision class.

Stainless steel. IP68 protection.
Output Resistance 1000 Ohm.

MAIN FEATURES

  • C3 PRECISION CLASS
  • STAINLESS STEEL CONSTRUCTION WITH LASER WELDING
  • IP68 PROTECTION, IP69K UPON REQUEST
  • CAPACITIES 10000 kg
  • SHIELDED CONNECTION CABLE
  • TEST CERTIFICATE PROVIDED AS STANDARD

TECHNICAL FEATURES

  • Minimum load cell verification interval Vmin = EMax / 10.000
  • Maximum number of verification intervals nLC = 3000
  • Combined error 0,017% of Full Scale Output (F.S.)
  • Full Scale Output 2mV/V +/- 0.5%
  • Temperature effect on zero 0,002% / °C
  • Temperature effect on full scale output 0,002% / °C
  • Compensated Temperature Range -10°C/+50°C
  • Operating Temperature Range -20°C/+60°C
  • Creep error after 30 minutes 0,02% F.S.
  • Maximum tolerated excitation voltage 15 VDC
  • Input Resistance 1100 ± 20 Ohm.
  • Output Resistance 1000 ± 20 Ohm.
  • Insulation Resistance >5000 MOhm
  • Safe Overload 120% F.S.
  • Ultimate Overload 300% F.S.
  • 6-wire shielded cable, 5m long, 5 mm diameter

ATEX VERSION

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
DOWNLOAD
Available versions
 
Code
Max
(kg)
SBX10000-1KL 10000
IP69K Protection
 CodeDescription
IP69KLC IP69K version for one loadcell.
Connection cables
 CodeDescription
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m
LCCBA Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m
LCCBM Shielded 4x0,34 mm² cable for moving applications. €/m
PRCB Protection sheathing for shielded cable. €/meter internal Ø 15mm.
Junction Boxes
 CodeDescription
JB4Q Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection rating, with 4 + 1 fairleads.
JB4QI Stainless steel equalisation box for connection with up to 4 load cells. IP65 protection rating, with 4 + 1 fairleads.
JC4Q Equalisation board for up to 4 cells. With UL marked PCB, Terminal block, plastic box and labels (if expected).
Available weight indicator/transmitter
 CodeDescription
DGT1S Weight transmitter on DIN bar, with 2 INPUTS and 2 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program.
DGT1 Weight transmitter for DIN bar. 5-key keypad, LED display, date/time, alibi memory, and multifunction weighing program.
DGT4 Transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing program.
DGTQ Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing program.
Options for ATEX version
 CodeDescription
ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
KZBA-1 ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
JB4QAI ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
JB4QA ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
EXCB6(S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m
LCCB Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m
KMB4-1 Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).
DCATEXMECH ATEX version for the PLATFORM / LOAD CELL MOUNTING KIT for zone 1/21 (for the load cells ATEX declaration see CCATEX code). Option to be offered only if the platform is ordered without the indicator, otherwise refer to the available certifications for the chosen weight indicator. Provided with safety instructions and ATEX EU declaration of conformity (EN, DE, FR, ES and IT).
DCATEXMB4 ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT).

Pdf product page All the specifications and images can be subject to variations and upgrades without prior notice.
ASSISTANCE