Shear Beam
|
SBX-1KL SERIES SHEAR BEAM LOAD CELLS, from 3000kg to 4500kg
|
SBX-1KL SERIES SHEAR BEAM LOAD CELLS, from 3000kg to 4500kg
|
|
|
|
|
| | | DIMENSIONS - DECODING STANDARD CABLE |
| | - NOTE: dimensions in mm
- Decoding of the standard cable colours
Colour | Function | -- | SHIELD | YELLOW | OUTPUT + | GREY | SENSE + | BROWN | INPUT + | WHITE | OUTPUT - | GREEN | INPUT - | PINK | SENSE - |
|
|
|
Stainless steel approved shear beam load cells, with low-power 1000 Ohm output resistance for mobile battery applications. Suitable for creating CE-M approved scales with 4 load cells, or for weighing tanks and hoppers, with the aid of its accessories.
CAPACITIES (kg): 3000, 4500.
OIML R60. C3 precision class.
Stainless steel. IP68 protection. Output Resistance 1000 Ohm.
|
|
Available versions
| Code | Max (kg) |
| SBX3000-1KL | 3000 |
| SBX4500-1KL | 4500 |
IP69K Protection
| Code | Description |
| IP69KLC | IP69K version for one loadcell. |
Base plates
| Code | Description |
| BPSBX5 | 5 mm base plate for SBX load cells capacity 3000-4500 kg . Size: 70 x 40 x 5 mm |
Mounting kits
| Code | Description |
| KSB5 | Stainless steel kit for assembling 1 SBK/SBX cell from 3000 to 5000kg. |
| KSB5H | Stainless steel articulated plate with M20x65mm threading. Applicable to SB.. load cells with capacity from 3000 to 5000 kg. To combine with BLKM20I bush. |
Foot
| Code | Description |
| SBFI3K-1 a> | Stainless steel articulated foot with 70 mm non-slip rubber support base. Threading M20 x 2,5 x 33,5. For SBxx cells up to 3000/5000kg. To combine with BLKM20I bush. |
| KSB5FI-1 a> | Stainless steel articulated foot with 60 mm non-slip rubber base. Threading M20 x 2.5 x 58.
|
| BLKM20I | Stainless steel M20 bush. |
Stay rod
| Code | Description |
| LNK2635 | Galvanized stay rod with ball-and-socket joints. Max 100 kN. For proper installation, 2xLNKST are needed. Note: They can’t be ATEX-certified. |
| LNKST | Single plate for stay rod. Fitted with fixing screw. (For proper installation, LNK2635 and a second LNKST are needed). Note: They can’t be ATEX-certified. |
Connection cables
| Code | Description |
| LCCB a> | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m |
| LCCBA | Armoured cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m |
| LCCBM a> | Shielded 4x0,34 mm² cable for moving applications. €/m |
| PRCB | Protection sheathing for shielded cable. €/meter internal Ø 15mm. |
Junction Boxes
| Code | Description |
| JB4Q a> | Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection rating, with 4 + 1 fairleads. |
| JB4QI a> | Stainless steel equalisation box for connection with up to 4 load cells. IP65 protection rating, with 4 + 1 fairleads. |
| JC4Q a> | Equalisation board for up to 4 cells. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
Available weight indicator/transmitter
| Code | Description |
| DGT1S a> | Weight transmitter on DIN bar, with 2 INPUTS and 2 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program.
|
| DGT1 a> | Weight transmitter for DIN bar. 5-key keypad, LED display, date/time, alibi memory, and multifunction weighing program. |
| DGT4 a> | Transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing program. |
| DGTQ a> | Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing program. |
Options for ATEX version
| Code | Description |
| ZBA1S a> | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| KZBA-1 a> | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
| JB4QAI a> | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| JB4QA a> | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| LCCB a> | Shielded cable 6x0.25 mm² (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 6 x O.D. €/m |
| EXCB6 | (S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m |
| KMB4-1 a> | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
| CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). |
| DCATEXMECH | ATEX version for the PLATFORM / LOAD CELL MOUNTING KIT for zone 1/21 (for the load cells ATEX declaration see CCATEX code). Option to be offered only if the platform is ordered without the indicator, otherwise refer to the available certifications for the chosen weight indicator. Provided with safety instructions and ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
Pdf product page
All the specifications and images can be subject to variations and upgrades without prior notice.
|
|