Analog
|
DINI ARGEO ANALOGUE COLUMN LOAD CELL, IN STAINLESS STEEL, “RCA” SERIES
|
DINI ARGEO ANALOGUE COLUMN LOAD CELL, IN STAINLESS STEEL, “RCA” SERIES
|
|
|
|
|
 |  |  | RCA LOAD CELL: CONNECTION CABLE |
|  |
Wiring Code | Colour | Function | WHITE | OUTPUT + | RED | INPUT + | YELLOW | OUTPUT - | BLUE | INPUT - |
|
|
|
Analogue version of compression load cells, ideal for CE-M approved weighbridges, tanks, silos, etc. Manufactured in STAINLESS STEEL, IP68 protection, 4000 divisions, fitted with “rodent proof” armoured cable.
CAPACITIES (kg): 30000.
OIML R60. C4 precision class.
Load cells with stainless steel body. Degree of protection IP68.
20m Armoured Rodent Resistant Cable, with standard Stainless Steel Armor.
Integrated Surge Arresters as Standard
Low Profile Height of only 130mm. Version available for ATEX environments.
|
|
Available versions
| Code | Max (kg) |
| RCA30C4  | 30000 |
Assembly kits
| Code | Description |
 | KRCA | Kit of 2 jointed cups for self-alignment and fixing plate. In zinc-plated steel. |
Junction Box / Boards - Cell cables
| Code | Description |
 | JB8Q-1 a> | Equalisation box for connection with up to 8 analogue load cells. Reinforced polyester box, with 8 + 1 PG11 cable glands. With surge arresters, PCB, Terminal block, plastic box and UL marked labels (if applicable). |
 | JB10Q a> | Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 cable glands. With surge arresters, PCB, Terminal block, plastic box and UL marked labels (if applicable). |
Analogue kit for weighbridges
| Code | Description |
 | WK630A | Kit for ANALOGUE weightbridges with 6 load cells. Composed of 3590ET indicator fitted with AF03 software, 2 inputs, 4 outputs and RS485 port, 6 RCA30C4 analogue load cells with KRCA mounting kit, and JB10Q equalisation box with 10 inputs. |
 | WK830A | Kit for ANALOGUE weightbridges with 8 load cells. Composed of 3590ET indicator fitted with AF03 software, 2 inputs, 4 outputs and RS485 port, 8 RCA30C4 analogue load cells with KRCA mounting kit, and JB10Q equalisation box with 10 inputs. |
Protection for junction box/electronic circuits
| Code | Description |
 | GELBOX a> | (S1) Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml. |
WARNING:
For JB10Q/JB10QD: 1200ml of gel required
Options for ATEX version
| Code | Description |
 | ZBA1S a> | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
 | KZBA-1 a> | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
 | JB4QAI a> | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
 | JB4QA a> | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
 | EXCB6 | (S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m. Maximum orderable length: 100 m (longer lengths available only upon request). |
 | KMB4-1 a> | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
 | CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
 | CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115°C Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). |
 | DCATEXMECH | ATEX version for the PLATFORM / LOAD CELL MOUNTING KIT for zone 1/21 (for the load cells ATEX declaration see CCATEX code). Option to be offered only if the platform is ordered without the indicator, otherwise refer to the available certifications for the chosen weight indicator. Provided with safety instructions and ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
 | DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
Pdf product page
All the specifications and images can be subject to variations and upgrades without prior notice.
|
|