DFW Series
|
"DFWLI": MULTIFUNCTION WEIGHT INDICATOR, IN IP68 STAINLESS STEEL CASE
|
"DFWLI": MULTIFUNCTION WEIGHT INDICATOR, IN IP68 STAINLESS STEEL CASE
|
|
|
|
Easy to programme and use, versatile and high performing weight indicator. The wide range of available functions and interfaces, make it suitable for multiple industrial and commercial weighing applications, such as floor scales, mobile weighing, etc. Case in IP68 stainless steel. CE-M approvable (OIML R-76/EN 45501).
|
|
Available versions
| Code | Description |
| DFWLI-2 | Weight indicator with 5-key keypad. IP68 stainless steel case, LCD backlit display, and standard weighing programme. |
| DFWLKI-2 | Weight indicator with 17-key keypad. IP68 stainless steel case, LCD backlit display, and standard weighing program. |
Optional power supply cords
| Code | Description |
| PWCORDUK | Version with BS1363 power cord (UK plug). |
| PWCORDCH | Power supply cord with SEV1011 plug (CH plug). |
| PWCORDUS | Version with US type B power cord (Japan, North and Central America). |
| PWCORDAUS | Version with AU power cord. |
Available firmwares
| Code | Description |
| DFWPK | Program for detecting weight peaks or kg to N conversion |
Junction Box / Boards - Load Cell cables
| Code | Description |
| LCCBC | (S1) Cable for connection between platform and indicator, l=50cm. Female connector to be soldered. |
| LCCB5C | (S1) LCCBC cable + 5m extension cable. |
| LCCB10C | (S1) LCCBC cable + 10m extension cable. |
Approval for sale to third parties
| Code | Description |
| KCEM a> | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
| ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Storing the weighs
| Code | Description |
| SWM a> | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
| USBDFWL-1 a> | (S1) Built-in USB port to store data on a USB driver. To be combined with DFWLI and DFWLKI weight indicators. Fitted with USB key for PC. |
PC software for managing weighbridges
| Code | Description |
| WEITRUCK-1 a> | PC software for vehicle weighing. It can be combined with DFW, DGT and 3590 series' weight indicators. Databases to store customer, material and vehicle data, management of the totals and programmable printouts. Alibi Memory is required for DFW/DGT (3590 series is equipped with alibi memory as standard). |
Printers/Labellers
| Code | Description |
| OBTPRB a> | (S1) Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. Thermal paper roll included as standard. |
| CODEPG | Service for loading a customised code-page on TPR printer (standard is PC437 - Central Europe, USA) |
| LP542TE a> | (S1) Thermal transfer or direct thermal labelling machine Supplied with standard peel mechanism. Maximum printing size 25400 x 108 mm. Maximum roll Ø 127 mm and width up to 112 mm.
Label roll and ribbon not included. |
| SMTPLUS-1 a> | (S1) Thermal transfer or direct termal labeller. Peel-off kit in option. Maximum print size 25400 x 108 mm. Maximum roll Ø 203 mm and width up to 118 mm.
Label roll and ribbon not included. |
| RSCBLP | (S1) RS232 cable l=1,5m for LP542xx, SMTPLUS, PR80 printers. |
| RSCBLP10M | (S1) RS232 cable l=10m for LP542xx, SMTPLUS, PR80 printers. |
| CNFSERV | Custom-made printouts for DFW and DFWL series. NET price. |
Communication Interfaces
| Code | Description |
| RSCBUSBPG a> | (S1) USB PC/RS232 converter cable, l=1,5m, with PG9. USB/RJ11 connector. For the connection to weight indicators with IP65, IP68 and IP69K protection system. |
| RSCBUSB485 a> | USB cable converter PC/RS485, l=1,5m. With metallic PG9 cable gland.
To be combined with an indicator fitted with optional or standard RS485 output. |
| OBRF2G4 a> | (S1) External 2.4 GHz radio module, cable l=3m. ABS IP65 protecting box, 3 m cable, power supply from weight indicator. Max. distance, in appropriate environmental and installation conditions: 45 m indoors, 140m outdoors. 39 configurable channels. |
| RF2G4 a> | (S1) Built-in 2.4 GHz radiofrequency module. Max. functioning distance in appropriate environmental and installation conditions: 45m indoors, 140m outdoors. Up to 39 configurable channels. (RF2G4 must be combined with another radio module). |
| DFIO-1 | (S1) Built-in 2 IN / 6 OUT interface (requires FW 05.05.00 or higher). |
| ETHD a> | (S1) Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
| RS485C | (S1) Built-in RS485 interface (mounting and cable gland excluded). |
| ALMEM-1 | (S1) Alibi memory (fiscal memory, max 120.000 weighs) for approved weight transmission to PC/PLC or data recording on MMC/USB. Built-in real time clock to print the date/time with PCB, screw terminal, plastic box and UL-marked labels.
If applicable, it requires FW 05.00.02 or higher. Not compatible with weight repeaters. |
| BLTH-3 a> | (S1) Built-in bluetooth interface. For wireless connection of the scale to tablets, smartphones, laptops or barcode scanners. Attention: this interface is not suitable for Master-Slave systems. |
| WIFITPWLK-2 a> | (S1) Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. |
Date&Time option
| Code | Description |
| DFCLK | (S1) Real time clock for printing/displaying of date and time. With UL marked PCB, screw terminal, plastic box and labels (if applicable). |
Connection cables
| Code | Description |
| RSCBRJ | (S1) RS232/C serial cable - DB9/RJ11 - l=1,5m. |
| RSCBRJ10M | (S1) RS232/C serial cable - DB9/RJ11 - l=10m. |
| ETHCBRJ | (S1) Ethernet cable, l=1,5m. Fitted with fairlead, for connection between indicator and PC network. |
Remote control
| Code | Description |
| TLRP | (S1) Radio frequency remote control and receiver with extension, for installations where other option boards with connection to AMP are required. |
Columns, supports brackets, visors
| Code | Description |
| STFR-1 | AISI 304 stainless steel fixing bracket with adjustable inclination. For weight indicator wall mounting. |
| CSP38I-1 | AISI 304 stainless steel column 450x450mm, h=917mm, Ø 38mm. For the indicators of the DINI ARGEO and SCALE HOUSE range.
|
| CSP38 | Stainless steel column 450x450mm, h=917, Ø 38mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
| CSP38D | Stainless steel column 350x350mm, h=750mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
Weight repeater software
| Code | Description |
| MSTSLV | Program to use the indicator as a repeater. It must be combined with the DFW and DGT weight indicators. |
Weight repeaters
| Code | Description |
| DGT100R-1 a> | Weight repeater with 100mm LED display. IP68 stainless steel case, 5-key keypad, air valve for regulating the humidity and the pressure. |
Options for ATEX version
| Code | Description |
| ZBA1S a> | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| KZBA-1 a> | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
| KMB4-1 a> | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
| DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
| JB4QA a> | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| JB4QAI a> | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
| EXCB6 | (S6) Blue shielded cable 6x0.22 mm², only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 °C. Minimum bending radius >/= 7 x O.D. €/m |
PG cable glands
| Code | Description |
| PG7M | 10 PG7 metallic cable gland set for weight indicators. Complete with rings and gaskets. |
| PG9M | 10 PG9 metallic cable gland set for weight indicators. Complete with rings and gaskets. |
| PG9PG11C | Kit of 10 metalic IP68 from PG9 to PG11 adapters (ø max cable 12mm) |
| PG9PG13C | Kit of 10 metalic IP68 from PG9 to PG13 adapters (ø max cable 12mm) |
Other options
| Code | Description |
| VENT | (S1) Valve for regulating humidity and pressure inside the indicator. Advised for IP68 applications.
|
| TECSUP | Technical assistance by telephone upon request. |
| UMAN | Printed user manual (Free download from the website). |
| TECMAN | Printed technical manual (Free download from the website). |
| ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET €. |
Pdf product page